This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. Products sold by come with ’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. is not an authorized distributor, affiliate, or representative for the brands we carry. "_HMI_CurrentPage" or something like that.? Thanks, Micheal Edited by lamboom I want the ST rung to be auto activated by the "existence" of the current page. an' I don't want to push some "Equals" button that activates an ST rung. I want to work with input variable data, and display of resulting variable data on that same page because, the input data creates the output data. that's just for calling pages from the NJ software. PS: I think it's in the NA's Variable Maping. Do you know the answer to the second question? the answer seems only to answer the first question, and ignores the second question.

omron sysmac studio page layers

But, what does it mean to "assign it to this system variable: "_HMI_CurrentPage". I get that you create a String-type variable: select STRING under the Type column.

omron sysmac studio page layers

Omron sysmac studio page layers how to#

This answer probably means something to someone who already knows how to do it. If the address values are directly linked with the page numbers as in NS series, you must write Visual Basic". You can change the screen by entering the name of the destination screen in the variable assigned to the system variable. "On the NJ, specify a String-type variable and assign it to “_HMI_CurrentPage”, a system variable that specifies the current screen. Last question: "Is it possible to switch the screen from the PLC? I s it also possible to report the current screen from NA to PLC? " Someone asks a two question, question, and this is the only answer: I would like to see them, before running the axis. Because, they mathematically depend upon the values of the variables you inputted. Basically, you input something, and other data displays on the same page, change in response. I need a small program to go live when a page is displayed, and always be calculating, and displaying different variables on the same page. I need a way to display variables that are calculated from inputted variables. The HMI page is live for inputting and displaying variable data but the CPU isn't doing any servo controlling. so that when a scale and a wave height is input as data, the wave height in mm, is displayed. I would like the data displays to be "live". "Scale" would also be a data input on this, or other HMI page. Īs an example, when I input values on a page like "wave height", and it might be in feet, There would be another data display object (on the same page) that indicates the height in millimeters however, that display in mm, would be based on a "Scale" factor. I'm looking for a way to set values or binary states to variables, depending on what "Page" was displayed on the HMI. But, that idea of a "script" that turns on and off looks good. It wasn't real clear how that would help do what I wanted.








Omron sysmac studio page layers